Premixed Traditional Render

Ezycoat Traditional Render is a premixed cement render with a slightly coarser grading of sand that produces a uniform andstayed appearance normally reserved for the renders of yester year. It’s versatility and ease of use make it the right choice when it comes to render. Ezycoat Traditional Render is a premixed render coat, which exhibits similar properties to a traditional sand ,cement render. Ezycoat Traditional Render is available in off white cement or the more traditional grey portland cement. The addition of additives based on Portland grey cement conforming to AS 3972 produces a leveling render with excellent adhesion and water resistant properties. Ezycoat Traditional Render has been specially developed for use on external/internal surfaces that require a rendered finish. It provides an even and consistent sand finish when sponged, ready for subsequent paint and/or Texture finishes. Ezycoat Traditional Render is suitable for use as a render or when mixed with Ezycoat Bond in the specified proportions (Refer to Ezycoat Bond Technical Data Sheet), can be applied to a thickness of 2.5mm and will exhibit excellent adhesion and strength. Ezycoat Traditional Render does not contain Lime, and as such makes it more compatible to Acrylic borne Paints and Texture finishes.

Ezycoat Traditional Render

Description: Ezycoat Traditional Render is a premixed cement render with a slightly coarser grading of sand that produces a uniform and stayed appearance normally reserved for the renders of yester year. It’s versatility and ease of use make it the right choice when it comes to render.

Surface Application: Suitable for application to Clay Brick, Concrete Block, Polystyrene Cladding, Koolwall Panel * Refer to Technical Data Sheets (TDS). or Ezyspec for application procedures.

Mixing Procedure: Requires the addition of water only when applied as a full render, in some cases it may require the addition of Ezycoat Bond refer to TDS.

Application Method: Ezycoat Traditional Render is applied by Steel Trowel , ruled and then sponge finished for best results.

Colour: Off White

Packaging: Environmentally Friendly Paper Bags 20kg.- 48/56 units per pallet

Coverage: 2 to 5 sqm per Bag, Consumption will varying depending on surface to be coated

  • Use
  • Use

    Ezycoat Traditional Render

    Contact Us

    1300566592

    Ezycoat Traditional Render is an easy to use single step trowel on and/or render pump apply able cement render which is suitable for leveling a range of masonry and cladded mediums(refer to Ezy BuildSpecs for the relevant building system). It will allow for the sequential application of architectural coatings such as Ezycoat Scratch/Sandstone etc. (See relevant Data Sheets on these products for additional information.) If this type of finish is not desired, then finishing Ezycoat Traditional Render with a sponge float will produce a render like finish quite easily, ready for the subsequent paint application.

    Before commencing application, ensure that the intended applied surface is free of any contaminants which may affect the performance of the render e.g. silicone coatings, curing oils and/or existing paint. Should this be the case then our office should be contacted for further advice on assessing the suitability of the surfaces to be coated. Ezycoat Traditional Render must not be applied to fiber cement and/or existing painted surfaces. All surfaces must be structurally sound prior to the application of Ezycoat Pump-Render. A visual inspection will need to be carried out prior to application to access the suitability of the surface and method of application.

    Ezycoat Traditional Render should be applied at no less than 2.5mm in thickness, however not exceeding 5mm in any one application and must be mixed in accordance to Ezy BuildSpecs for the relevant product to which it is being applied to.

  • Application
  • Application

    Ezycoat Traditional Render Mixing Procedures

    Contact Us

    1300566592

    MANUAL MIXING PROCEDURE
    To mix Ezycoat Traditional Render it is recommended that you use a clean empty 20L bucket to accept the volume of mixture from the 20kg Ezycoat Traditional Render bag. Filling the bucket with approximately 2 litres of clean potable water and using a high speed mixing drill fitted with a paste mixing blade. The contents of the Ezycoat Traditional Render bag should be slowly poured into the bucket whilst operating the mixer. This will be a safer and easier process with the assistance of another individual.

    As the Ezycoat Traditional Render is poured into the bucket additional water may be required to produce a smooth workable paste. Normally a total of 3.5 to 4 litres of water may need to be added to each bag of Ezycoat Traditional Render to achieve a good workable creamy paste. Do Not Add Excess Water.

    Once the Ezycoat Traditional Render has been vigorously agitated and worked into a smooth compact paste it is ready for application. Using a Plasterer’s Hawk and steel trowel, the Ezycoat Traditional Render paste can be scooped onto the Plasterer’s Hawk and in turn evenly spread onto the surface using the steel trowel.

    PUMP MIXING PROCEDURE
    When using a pump for application, the Ezycoat Traditional Render is ready to be poured directly into the hopper. It is essential that the pump specifications be checked prior to commencement of use as specifications may vary from pump manufacturers; if in doubt please contact our offices for further advice on pump requirements.

    Should the applicating surface exhibit extreme suction that causes unusual quick drying out of the Ezycoat Traditional Render it may be necessary to pre seal the walls using diluted Ezycoat Bond (Refer to Ezycoat Bond
    Technical Data Sheet). Should the applicating surface have varying undulations then 1 coat of Ezycoat Traditional
    Render to specifications should be applied as a leveling coat prior to the application of Traditional Render.

    Once complete, the surface should be allowed to dry for approximately 48 hours prior to any subsequent Ezycoat Masonry Sealer or Membrane paint finish applications. This will assist the curing and strengthening process of the Ezycoat Traditional Render. The render surface should not be left unpainted for any more than 14 days after the completion of rendering. Failure to do so may result in cracks forming in the surface.

    The application of Ezycoat Traditional Render should not be carried out in extremely hot and windy conditions. It is recommended that Ezycoat Traditional Render application be carried out in shaded areas where possible. This will assist with ease of application.

    Applicators should not apply large areas of Ezycoat Traditional Render that they are unable to apply and finish within the Ezycoat Traditional Render’s drying period.

  • Technical Spec
  • Technical Spec

    Ezycoat Traditional Render

    Contact Us

    1300566592

    Due to the many different proprietary building systems available on the market, it is highly recommended that you contact our offices and request a copy of the Ezycoat specification for the building system you are using. EZYBUILD SPECS are readily available upon request either from our company representatives or our offices.

    For more detailed information with regards this product and any safety concerns, please refer to the Material Safety Data Sheets available from Active Building Systems Pty Ltd upon request.

    Ezycoat Traditional Render is to be applied by suitably licensed persons holding a license for this trade as recognised by the legislative building authority for the relevant state to which the work is being carried out. Misuse of this product and/or non compliance with technical specifications will void any warranties weather verbal or written. Active Building Systems Pty Ltd reserves the right to change, update and republish these specifications without any notice. It is the user’s responsibility to attain the most current publication of Ezycoat Specifications from Active Building Systems Pty Ltd.

  • Data
  • Data

    Ezycoat Traditional Render Data

    Contact Us

    1300566592

    Consumption: 2 to 5 sqm per 20 kg Bag. Based on 5mm to 2mm coating thickness
    Density: Approx. 1500kg/Cu.m
    BagSize: 20 Kg.
    Classification: non-dangerous goods
    Colours: Natural Grey or off white
    Important Notes: Do not apply in temperatures below 10 degrees Celsius or 24 hrs prior to or after wet & rainy conditions. Do not apply in moist conditions. All walls must be free of moisture prior to application. All surfaces should be cleaned and free of any contaminant, releasing agent, fungal growth which may affect the performance of these coatings. Any imperfections which may become visible in the finished surface should be patched and leveled with Ezycoat
    Patching compounds. Any structural imperfections and/or cracks will need to stabilised prior to any further applications. The durability of the product in its original confection is guaranteed for 8 months as long as it is not exposed to direct sunlight or temperatures below 6 degrees. Ezycoat Traditional Render is not suitable for use in areas prone to water logging, submersion, continually damp and/or below ground. Walls were Ezycoat Traditional Render is to be applied must be free draining. In the case of retaining walls the rear of the wall must be engineered to prevent any penetration of moisture or water through the wall in to the rear of the Ezycoat Traditional Render. Failure to do so will result in damage to the Ezycoat Traditional Render and is not covered by warranty. Excess Waste product should be disposed of in responsible manner following guidelines as set out by the local council’s bi-laws and Waste Disposal Procedures.